Bear Lodge Plan of Operations - page 536

Interim Baseline Radiological Investigation Report
November 14, 2012
Bear Lodge Project, for Rare Element Resources, Ltd.
Rev.1
48
9.0
AMBIENT GAMMA EXPOSURE RATES
Ambient exposure rates were determined for three quarters, using optically stimulated
luminescent (OSL) detectors supplied and analyzed by Landauer, Inc. The monitoring periods
were as follows:
Period 1: November 9-10 , 2011 to January 20, 2012
Period 2: February, 2012 to April, 2012
Period 3: April, 2012 to August ,2012
The OSLs were deployed at each of the four AMS locations.
The results for the OSLs, listed in Table 2-4, were reported in millirem (mrem) dose equivalents
as follows:
AMS-01: 157 mrem per year (mrem/yr)
AMS-02: 438 mrem/yr
AMS-03: 150 mrem/yr
AMS-04: 164 mrem/yr
Table 9.1. Ambient Exposure Rates Determined Using OSLs
Location ID
Date Deployed
Date
Retrieved
Exposure
Days
Dose for
Monitoring
Period (mrem)
Average Dose
Rate
(mrem/d)
AMS-01
11/16/11
01/20/12
65
27.9
0.43
02/14/12
04/13/12
59
26.2
04/13/12
08/09/12
118
50.9
AMS-02
11/16/11
01/20/12
65
112.8
1.2
02/14/12
a
04/13/12
59
-
04/13/12
08/09/12
118
192.2
AMS-03
11/16/11
01/20/12
65
21.5
0.41
02/14/12
04/13/12
59
24.0
04/13/12
08/09/12
118
53.0
AMS-04
11/16/11
01/20/12
65
34.7
0.45
02/02/12
04/17/12
75
28.0
04/17/12
08/09/12
114
52.3
Notes:
a
Dosimeter not deployed for this period.